Home Product Eaton Bussmann FNQ-R-1/2 0.5A 600V AC Class CC Time-Delay Fuse

Eaton Bussmann FNQ-R-1/2 0.5A 600V AC Class CC Time-Delay Fuse

( 0 )

United Arab Emirates dirham (د.إ) - AED
  • United Arab Emirates dirham (د.إ) - AED
  • United States dollar ($) - USD

The Eaton Bussmann FNQ-R-1/2 is a 0.5A, 600V AC LIMITRON Class CC time-delay fuse designed for compatible industrial control circuits, small control transformers, line protection and branch circuits. Its dual-element, current-limiting design accommodates specified inrush currents and provides a 200 kA interrupting rating at 600V AC. It features ferrule ends and a rejection-style design for compatible Class CC fuse holders.

SKU: DS-01129
Brand:
QUICK PRODUCT ENQUIRY

Request a Quote

Send your requirement and our team will contact you.

Eaton Bussmann FNQ-R-1/2 0.5A 600V AC Class CC Time-Delay Fuse
OR

Description

The Eaton Bussmann FNQ-R-1/2 is a LIMITRON series Class CC fuse designed to provide overcurrent protection in compatible electrical and industrial control circuits. Its dual-element, time-delay characteristics help accommodate specified temporary inrush currents while protecting against qualifying overcurrent and short-circuit conditions.

With a 0.5A current rating and 600V AC voltage rating, this fuse is suitable for equipment designed to use the FNQ-R-1/2 model and its specific protection characteristics.

Technical Specifications

Specification Details
Brand Eaton Bussmann
Series LIMITRON FNQ-R
Model FNQ-R-1/2
Rated Current 0.5A (500mA)
Rated Voltage 600V AC
Fuse Class Class CC
Interrupting Rating 200 kA at 600V AC
Operating Characteristic Dual-Element, Current-Limiting Time-Delay
Response Time 12 Seconds at 200% of Rated Current
Connection Ferrule Ends
Fuse Indication Non-Indicating
Body Material Melamine Tube
Approximate Dimensions 10.3 mm Diameter × 38.1 mm Length

Key Features and Benefits

Time-delay operation: Helps accommodate specified temporary inrush currents, including those associated with compatible small control transformers.

Current-limiting protection: Designed to limit fault-current energy under applicable circuit conditions.

Class CC rejection design: Intended for compatible Class CC fuse holders, helping prevent installation in certain incompatible holders.

Compact cylindrical construction: Ferrule-type ends support installation in compatible fuse blocks and industrial control equipment.

Typical Applications

Depending on the circuit design and equipment requirements, the FNQ-R-1/2 may be used for:

– Industrial control panels
– Small control transformer protection
– Electrical line protection
– Compatible branch circuits
– Industrial equipment control circuits

Reviews

There are no reviews yet.